Wedge Flow Meter is used as primary element in flow measurement of liquid, gas and steam according to the differential pressure principle.

Design and calculation standards :

EN, PED 97/23 EC, ANSI/ASME and RW Miller

Sizes

DN 50 -900 2"-36"

Pressure rating :

PN 10 - 250, 150 -1500 lbs

Material :

Carbon steel P235GH, P250GH, P265GH, A105N, A106 Gr. B, AISI 316, Duplex, Super Duplex,

6Mo, heat resisting steels, other materials on request

Mounting style :

Flanges connection according to DIN or ANSI

Pressure taps :

DN 50 and DN 80, 2” and 3”

Flange facing :

Flat or raised face according to DIN 2526 or flat, raised face

or ring type joint according to ANSI B 16.5

Element ratio (H/D) :

0,2, 0,3, 0,4 and 0,5 (0,4 is standard).


Technical Data

Accuracy :

+/- 4-5 % (un-calibrated), +/- 0,5 % (calibrated).

Repeatability :

+/- 0,2 %

Pressure loss :

40 % of measured differential pressure with ratio H/D 0,4

Limits for Reynolds No. :

Re > 500

Viscosity :

Up to 3000 Cp

Installation requirement :

down to 5 x D up-stream and 2 x D down-stream.